Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April - May 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Study
Cross-reference
Reason / purpose:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
XU-18838.00: lot JHY 1307
Purity: 98.9%

Results and discussion

Flash point
Flash point:
>= 256 - <= 260 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Conclusions:
Fp = 258 +/- 2 °C under 1 atmosphere.