melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to an appropriate EU test method, and in compliance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report Date:
2003

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
differential scanning calorimetry (DSC)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
thermal analysis

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
-63.7 °C
Atm. press.:
other: atmosphere of Helium
Decomposition:
no
Sublimation:
no
Remarks on result:
other: no further information available