Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to an appropriate EU test method, and in compliance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report Date:
2003

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
DIN 51794
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
295 °C
Atm. press.:
973.9 hPa
Remarks on result:
other: no further data available