Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 201-969-4 | CAS number: 90-15-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Explosiveness
Administrative data
Link to relevant study record(s)
- Endpoint:
- explosiveness, other
- Remarks:
- according to EEC method A.14
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 21 December 2016 to 12 January 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.14 (Explosive properties)
- Version / remarks:
- Regulation (EC)440/2008
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: A017 / Batch Number : 7215604684
- Expiration date of the lot/batch: NA
- Purity test date: 09 september 2016
- Purity : 99.1% ±0.1%
- Re-analysis date : NA
- Description : Cream / beige to grey flakes
Relative Density : 1.28 g/cm3 (data taken from SDS)
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: NA
- Stability under test conditions: NA
- Solubility and stability of the test substance in the solvent/vehicle: NA
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: NA
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: no, sample is tested as received.
- Preliminary purification step (if any): no
- Final dilution of a dissolved solid, stock liquid or gel: no
- Final preparation of a solid: no - Key result
- Parameter:
- sensitiveness to impact: impact energy (J)
- Value:
- 40
- Remarks on result:
- not sensitive to impact using an impact energy of 40 J
- Key result
- Parameter:
- sensitiveness to friction: friction load (N)
- Value:
- 360
- Remarks on result:
- not sensitive to friction using a friction load of 360 N
- Key result
- Parameter:
- thermal sensitivity - Koenen test: diameter of the orifice plate
- Remarks:
- Orifice diameters of 6 mm and 2 mm
- Value:
- 2
- Remarks on result:
- not thermal sensitive if heated under defined confinement
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- In the conditions of the test, the test item is not mechanical sensitive with respect to the shock and friction and it is not thermally sensitive.
- Executive summary:
The explosive properties of the test item were determined according to the test method A.14 'Explosive Properties' as described in Directive 440/2008 and according to GLP.
For the sensitivity to shock, a series of six tests was performed dropping the 10 kg mass from 0,4 m (40 J) on the sample of A017 using Bam Fallhammer apparatus. The sample was observed to exhibit no reaction at 40 J.The test result is therefore considered Negative (-) for the shock(BAM Impact).
To assess the sensitivity to friction, aseries of six tests was performed with a load of 360 N on the sample of A017 using Bam Friction
apparatus. The sample of A017 was observed to exhibit no reaction at 360 N. The test result is therefore considered Negative (-) for the friction.
For the thermal sensitivity a series of three tests with a 6.0 mm diameter orifice plate and a series of three tests with a 2.0 mm
diameter orifice plate were performed on the sample A017 using Koenen tube apparatus. The test item did not exhibit an explosion when submitted to heat. The test result is therefore considered Negative (-) for the heat.
In the conditions of the test, the substance A017 is not mechanical sensitive with respect to the shock and friction, and it is not thermally sensitive. It did not demonstrated explosive properties.
Reference
Description of key information
In the conditions of the test, the test item is not mechanical sensitive with respect to the shock and friction and it is not thermally sensitive.
Key value for chemical safety assessment
- Explosiveness:
- non explosive
Additional information
The explosive properties of the test item were determined according to the test method A.14 'Explosive Properties' as described in Directive 440/2008 and according to GLP.
For the sensitivity to shock, a series of six tests was performed dropping the 10 kg mass from 0,4 m (40 J) on the sample of A017 using Bam Fallhammer apparatus. The sample was observed to exhibit no reaction at 40 J.The test result is therefore considered Negative (-) for the shock(BAM Impact).
To assess the sensitivity to friction, a series of six tests was performed with a load of 360 N on the sample of A017 using Bam Friction
apparatus. The sample of A017 was observed to exhibit no reaction at 360 N. The test result is therefore considered Negative (-) for the friction.
For the thermal sensitivity a series of three tests with a 6.0 mm diameter orifice plate and a series of three tests with a 2.0 mm
diameter orifice plate were performed on the sample A017 using Koenen tube apparatus. The test item did not exhibit an explosion when submitted to heat. The test result is therefore considered Negative (-) for the heat.
In the conditions of the test, the substance A017 is not mechanical sensitive with respect to the shock and friction, and it is not thermally sensitive. It did not demonstrated explosive properties.
Justification for classification or non-classification
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.