Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Lab and Guideline Method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report Date:
1999

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Batch No GST7-18099

Results and discussion

Vapour pressure
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0 hPa

Applicant's summary and conclusion

Executive summary:

the vapour pressure of Pyrazole DHE is determinated at 3*10Exp -8 hPa