Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study perfomed in GLP-Lab

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report Date:
1999

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
Type of method:
differential scanning calorimetry
Remarks:
Pre-test for EEC Test A2

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Boiling point
Decomposition:
yes
Decomp. temp.:
200 °C

Any other information on results incl. tables

No boiling point can be observerd upo to the decomposition temperature of 200 °C

Applicant's summary and conclusion

Conclusions:
No boiling point can be observerd uo to the decomposition temperature of 200 °C
Executive summary:

No boiling point can be observerd uo to the decomposition temperature of 200 °C