Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 21, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Decomposition:
yes
Decomp. temp.:
> 170 °C

Three DSC measurements with a heating rate of 10 K/min in aluminium crucibles with a hole showed a multistage endothermal effect in the temperature range of 120 – 240 °C with no clear melting point (onset). The 1st endothermal effect in the temperature range occurred in the temperature range 130 – 150 °C. The 2nd endothermal effect in the temperature range 170 – 210 °C was attributed to decomposition. The test item showed no melting.

The results of the DSC measurements are summarized in Table 1.

Table1: Melting point (DSC measurements)

Ident No.

Test item /

mg

Starting temperature /

°C

Final test temperature /

°C

Temperature range (melting) /

°C

Onset /

°C

Crucible

Observations after the measurement

36168

10.09

25

500

120 –240

Multi-stage

Aluminium with a hole

Test item was a black solid after the measure-ment: 62 % mass loss

36170

9.99

25

150

130 – 150

Multi-stage

Aluminium with a hole

Test item was a red solid after the measure-ment: 4 % mass loss

36172

8.72

25

250

130 - 210

Multi-stage

Aluminium with a hole

Test item was a black solid after the measure-ment: 26 % mass loss

The test item showed no melting up to 170 °C. The test item decomposed.

Executive summary:

The test item showed no melting up to 170 °C. The test item decomposed.

Description of key information

The test item showed no melting up to 170 °C. The test item decomposed.

Key value for chemical safety assessment

Additional information