Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 July 2018 to 14 August 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Version / remarks:
2017
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Niobium hydride
EC Number:
237-769-9
EC Name:
Niobium hydride
Cas Number:
13981-86-7
Molecular formula:
HNb
IUPAC Name:
niobium(1+) hydride
Test material form:
solid
Details on test material:
- Appearance: Silver grey solid
- Storage: At room temperature

Test animals / tissue source

Species:
cattle
Strain:
not specified
Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: Bovine eyes from young cattle were obtained from the slaughterhouse.
- The eyes were excised by a slaughterhouse employee as soon as possible after slaughter.
- Storage, temperature and transport conditions of ocular tissue: Eyes were collected and transported in physiological saline in a suitable container under cooled conditions.

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied: 310.0 to 367.8 mg

VEHICLE
- Amount applied: Since no workable suspension of the test material in physiological saline could be obtained, the test material was used as delivered and added pure on top of the corneas.
Duration of treatment / exposure:
240 ± 10 minutes
Duration of post- treatment incubation (in vitro):
90 ± 5 minutes with Sodium Fluorescein
Number of animals or in vitro replicates:
Three corneas were selected at random for each treatment group.
Details on study design:
SELECTION AND PREPARATION OF CORNEAS
- The eyes were checked for unacceptable defects, such as opacity, scratches, pigmentation and neovascularisation by removing them from the physiological saline and holding them in the light. Those exhibiting defects were discarded.
- The isolated corneas were stored in a petri dish with cMEM (Earle’s Minimum Essential Medium (Life Technologies, Bleiswijk, The Netherlands) containing 1 % (v/v) L-glutamine (Life Technologies) and 1 % (v/v) Foetal Bovine Serum (Life Technologies)). The isolated corneas were mounted in a corneal holder (one cornea per holder) of BASF (Ludwigshafen, Germany) with the endothelial side against the O-ring of the posterior half of the holder. The anterior half of the holder was positioned on top of the cornea and tightened with screws. The compartments of the corneal holder were filled with cMEM of 32 ± 1 °C. The corneas were incubated for the minimum of 1 hour at 32 ± 1 °C.


QUALITY CHECK OF THE ISOLATED CORNEAS
- After the incubation period, the medium was removed from both compartments and replaced with fresh cMEM. Opacity determinations were performed on each of the corneas using an opacitometer (BASF-OP3.0, BASF, Ludwigshafen, Germany). The opacitometer was calibrated using reference holders before use. The opacity of each cornea was read against a cMEM filled chamber, and the initial opacity reading thus determined was recorded. Corneas that had an initial opacity reading higher than 7 were not used.


NUMBER OF REPLICATES: 3


NEGATIVE CONTROL USED: Physiological saline


POSITIVE CONTROL USED: 20 % (w/v) Imidazole prepared in physiological saline.


APPLICATION DOSE AND EXPOSURE TIME: 310.0 to 367.8 mg for 240 ± 10 minutes.


TREATMENT METHOD:
- The medium from the anterior compartment was removed and 750 µL of the negative control and 20 % (w/v) Imidazole solution (positive control) were introduced onto the epithelium of the cornea. The test material was weighed in a bottle and applied directly on the corneas using the open-chamber method in such a way that the cornea was completely covered (310.0 to 367.8 mg). The holder was slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the solutions over the entire cornea. Corneas were incubated in a horizontal position for 240 ± 10 minutes at 32 ± 1 °C.


REMOVAL OF TEST SUBSTANCE
- After the incubation the solutions and the test material were removed and the epithelium was washed at least three times with MEM with phenol red (Earle’s Minimum Essential Medium Life Technologies).


METHODS FOR MEASURED ENDPOINTS:
- Possible pH effects of the test material on the corneas were recorded.

- Corneal opacity: Each cornea was inspected visually for dissimilar opacity patterns. The medium in the posterior compartment was removed and both compartments were refilled with fresh cMEM and the opacity determinations were performed. The opacity of a cornea was measured by the diminution of light passing through the cornea. The light was measured as illuminance (I = luminous flux per area, unit: Lux) by a light meter. The opacity value (measured with the device OP-KIT) was calculated according to:

Opacity = [(I0 / I) − 0.9894 ] / 0.0251

With I0 the empirically determined illuminance through a cornea holder but with windows and medium, and I the measured illuminance through a holder with cornea. The change in opacity for each individual cornea (including the negative control) was calculated by subtracting the initial opacity reading from the final post-treatment reading. The corrected opacity for each treated cornea with the test material or positive control was calculated by subtracting the average change in opacity of the negative control corneas from the change in opacity of each test material or positive control treated cornea. The mean opacity value of each treatment group was calculated by averaging the corrected opacity values of the treated corneas for each treatment group.

- Corneal permeability: Following the final opacity measurement, permeability of the cornea to Na-fluorescein (Sigma-Aldrich, Germany) was evaluated. The medium of both compartments (anterior compartment first) was removed. The posterior compartment was refilled with fresh cMEM. The anterior compartment was filled with 1 mL of 5 mg Na-fluorescein/mL cMEM solution (Sigma-Aldrich Chemie GmbH, Germany). The holders were slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the sodium-fluorescein solution over the entire cornea. Corneas were incubated in a horizontal position for 90 ± 5 minutes at 32 ± 1 °C. After the incubation period, the medium in the posterior compartment of each holder was removed and placed into a sampling tube labelled according to holder number. 360 µL of the medium from each sampling tube was transferred to a 96-well plate. The optical density at 490 nm (OD490) of each sampling tube was measured in triplicate using a microplate reader (TECAN Infinite® M200 Pro Plate Reader). Any OD490 that was 1.500 or higher was diluted to bring the OD490 into the acceptable range (linearity up to OD490 of 1.500 was verified before the start of the experiment). OD490 values of less than 1.500 were used in the permeability calculation. The mean OD490 for each treatment was calculated using cMEM corrected OD490 values. If a dilution has been performed, the OD490 of each reading of the positive control and the test material was corrected for the mean negative control OD490 before the dilution factor was applied to the reading.


SCORING SYSTEM: In Vitro Irritancy Score (IVIS)

- The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:

In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value)

- Additionally the opacity and permeability values were evaluated independently to determine whether the test material induced irritation through only one of the two endpoints.

- The IVIS cut-off values for identifying the test materials as inducing serious eye damage (UN GHS Category 1) and test materials not requiring classification for eye irritation or serious eye damage (UN GHS No Category) are given hereafter:
IVIS ≤ 3: No Category
IVIS > 3; ≤ 55: No prediction can be made
IVIS >55: Category 1

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
in vitro irritation score
Run / experiment:
First experiment
Value:
1.8
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
other: Since the results from the three corneas were spread over 2 categories (-0.5, -0.9 and 6.8 respectively), the test was inconclusive and a repeat experiment was performed.
Irritation parameter:
in vitro irritation score
Run / experiment:
Second experiment
Value:
-0.6
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
FIRST EXPERIMENT
- In the first experiment, the individual in vitro irritancy scores for the negative controls ranged from 0.9 to 2.0. The corneas treated with the negative control material were clear after the 240 minutes of treatment. The individual positive control in vitro irritancy scores ranged from 137 to 173. The corneas treated with the positive control were turbid after the 240 minutes of treatment.
- The corneas treated with the test material showed opacity values ranging from -2.5 to 0.3 and permeability values ranging from 0.106 to 0.436. The corneas were clear after the 240 minutes of treatment with the test material. No pH effect of the test material was observed on the rinsing medium. Hence, the in vitro irritancy scores ranged from -0.9 to 6.8 after 240 minutes of treatment with the test material.
- The mean in vitro irritancy score was 1.8 after 4 hours of treatment with the test material. Since the results were spread over 2 categories (-0.5, -0.9 and 6.8 respectively), the test was inconclusive and a repeat experiment was performed.

SECOND EXPERIMENT
- In the second experiment, the individual in vitro irritancy scores for the negative controls ranged from 2.7 to 2.9. The corneas treated with the negative control material were clear after the 240 minutes of treatment. The individual positive control in vitro irritancy scores ranged from 166 to 185. The corneas treated with the positive control were turbid after the 240 minutes of treatment.
- The corneas treated with the test material showed opacity values ranging from -2.3 to -1.2 and permeability values ranging from 0.013 to 0.139. The corneas were clear after the 240 minutes of treatment with the test material. No pH effect of the test material was observed on the rinsing medium. Hence, the in vitro irritancy scores ranged from -1.9 to 0.9 after 240 minutes of treatment with the test material.


ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: The negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas.
- Acceptance criteria met for positive control: The mean in vitro irritancy score of the positive control (20 % (w/v) Imidazole) was 159 and 176 in the first and second experiment, respectively and within two standard deviations of the current historical positive control mean.
- It was concluded that the test conditions were adequate and that the test system functioned properly.

Any other information on results incl. tables

Table 1: Summary of Opacity, Permeability and In Vitro Scores

Experiment

Treatment

Mean Opacity

Mean Permeability

Mean IVIS*

1

Negative Control

1.5

0.006

1.6

Positive Control

123

2.387

159

Test Material

-1.4

0.217

1.8

2

Negative Control

2.3

0.029

2.8

Positive Control

128

3.175

176

Test Material

-1.9

0.086

-0.6

* Calculated using the negative control mean opacity and mean permeability values for the positive control and test material. In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value).

Applicant's summary and conclusion

Interpretation of results:
other: Not classified in accordance with EU criteria
Conclusions:
Under the conditions of this study, since the test material induced an IVIS ≤ 3 in 5 out of 6 corneas, no classification is required for eye irritation or serious eye damage.
Executive summary:

The eye hazard potential of the test material was investigated in accordance with the standardised guideline OECD 437, under GLP conditions.

The objective of this study was to evaluate the eye hazard potential of the test material as measured by its ability to induce opacity and increase permeability in an isolated bovine cornea using the Bovine Corneal Opacity and Permeability test (BCOP test). The eye damage of the test material was tested through topical application for approximately 240 minutes. Since no workable suspension in physiological saline could be obtained, the test material was used as delivered and added pure on top of the corneas.

In the first experiment, the negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas. The mean in vitro irritancy score of the positive control (20 % (w/v) Imidazole) was 159 and within two standard deviations of the current historical positive control mean. It was therefore concluded that the test conditions were adequate and that the test system functioned properly.

The mean in vitro irritancy score was 1.8 after 4 hours of treatment with the test material. Since the results were spread over 2 categories (-0.5, -0.9 and 6.8 respectively), the test was inconclusive and a repeat experiment was performed.

In the second experiment, the negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas. The mean in vitro irritancy score of the positive control (20 % (w/v) Imidazole) was 176 and within two standard deviations of the current historical positive control mean. It was therefore concluded that the test conditions were adequate and that the test system functioned properly.

The test material did not induce ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of 1.8 and -0.6 after 4 hours of treatment in the first and second experiment, respectively.

Under the conditions of this study, since the test material induced an IVIS ≤ 3 in 5 out of 6 corneas, no classification is required for eye irritation or serious eye damage.