Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes
Type of method:
rotational viscometer (dynamic)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 3 000
Remarks on result:
other: Bardap 26 AS demonstrated non-Newtonian flow behaviour under the conditions of the test.
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 400
Remarks on result:
other: Bardap 26 AS demonstrated non-Newtonian flow behaviour under the conditions of the test.

Results summary

Sample

Temperature (°C)

Spindle speed (rpm)

Dynamic viscosity

(mPa. s)

mean values

A

20

0.3-2.5

2348.7

B

20

0.3-2.5

4498.0

 

 

 

 

A

40

1.5-20.0

417.1

B

40

1.5-20.0

433.8

Conclusions:
Bardap 26 AS demonstrated non-Newtonian flow behaviour.
Executive summary:

The study was performed in year 2006 in accordance with OECD Test Guideline 114 using a rotational viscometer. The mean measured dynamic viscosity of the test substance was approx. 3000 mPa.s at 20°C and approx. 400 mPa.s at 40°C. Bardap 26 AS demonstrated non-Newtonian flow behaviour.

Description of key information

The study was carried out in accordance with OECD Test Guideline 114 using a rotational viscometer. The mean measured dynamic viscosity of the test substance was approx. 3000 mPa.s at 20°C and approx. 400 mPa.s at 40°C. Bardap 26 AS demonstrated non-Newtonian flow behaviour.

Key value for chemical safety assessment

Viscosity:
3 000 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The study was carried out in accordance with OECD Test Guideline 114 using a rotational viscometer. The mean measured dynamic viscosity of the test substance was approx. 3000 mPa.s at 20°C and approx. 400 mPa.s at 40°C. Bardap 26 AS demonstrated non-Newtonian flow behaviour.