Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 2021 to December 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Specific details on test material used for the study:
Batch number: CT20201015
Re-test date: 10th September 2022
Storage conditions: store in a cool dry place
Key result
Type:
relative density
Density:
1.661 g/cm³
Temp.:
20 °C
Conclusions:
The test item 6FDA has a relative density of 1.6615 g/cm-3 at 20 oC.
Executive summary:

The relative density of the test item 6FDA was determined using the pycnometer method in accordance with OECD Guideline 109.  The relative density of 6FDA was determined to be 1.6615 at 20 oC.

Description of key information

The relative density of the test item 6FDA was determined using the pycnometer method in accordance with OECD Guideline 109.  The relative density of 6FDA was determined to be 1.6615 g/cm-3 at 20 oC.

Key value for chemical safety assessment

Relative density at 20C:
1.661