Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
92 °C
Atm. press.:
756 mm Hg

RESULTS:

Determination 1: 92.0 °C

Determination 2: 92.0 °C

The atmospheric pressure was 756 mm Hg.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance was found to be 92 °C.
Executive summary:

The flash point of the test substance has been measured in accordance with EU Method A.9 and in compliance with GLP. A flash point of 92 ± 2 °C has been determined at 759 mm Hg.

Description of key information

92 °C at 101 kPa, test substance in technical material, closed cup method, EU Method A.9, Husband 1998

Key value for chemical safety assessment

Flash point at 101 325 Pa:
92 °C