Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Reliability rating was 1 because freezing point determination followed EC Method A.1 and OECD Method 102 and was carried out under GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
Freezing point
GLP compliance:
yes
Type of method:
method to determine freezing temperature

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
< -25 °C
Atm. press.:
101.3 hPa
Remarks on result:
other: Substance did not freeze at below -25 C

Applicant's summary and conclusion

Conclusions:
The freezing point of the test substance was determined to be <-25C using the EC Method A.1 /OECD Method 102.
Executive summary: