Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Remarks:
Explosion Hazard Testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.11.2000 to 07.02.2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted to GLP
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
Nozzle diameter: 2 mm
Value:
1
Number of fragments:
0
Remarks on result:
not determinable
Remarks:
Reaction initiation after 24 seconds - no fragments, cartridge unchanged
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
Nozzle diameter: 2 mm
Value:
2
Number of fragments:
0
Remarks on result:
not determinable
Remarks:
Reaction initiation after 21 seconds - no fragments, cartridge unchanged
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
Nozzle diameter: 2 mm
Value:
3
Number of fragments:
0
Remarks on result:
not determinable
Remarks:
Reaction initiation after 20 seconds - no fragments, cartridge unchanged
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
Nozzle diameter: 6 mm
Value:
4
Number of fragments:
0
Remarks on result:
not determinable
Remarks:
Reaction initiation after 22 seconds - no fragments, cartridge unchanged
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
Nozzle diameter: 6 mm
Value:
5
Number of fragments:
0
Remarks on result:
not determinable
Remarks:
Reaction initiation after 24 seconds - no fragments, cartridge unchanged
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
Nozzle diameter: 6 mm
Value:
6
Number of fragments:
0
Remarks on result:
not determinable
Remarks:
Reaction initiation after 22 seconds - no fragments, cartridge unchanged
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not determinable
Remarks:
Drop-weight test. No optical change in product when a mass of 10 kg is dropped from a height of 40 cm. Test was repeated six times.
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks:
Pin pressure: 360 N.
Remarks on result:
not sensitive to friction using a friction load of 360 N
Remarks:
Test repeated eight times, all repeats yielded a negative result.
Interpretation of results:
GHS criteria not met
Conclusions:
Triflumuron is not explosive when heated under defined confinement. Triflumuron is not sensitive to shock (mechanical sensitivity: Drop-Weight Test). Triflumuron is not sensitive to friction (mechanical sensitivity: Friction Mill).

Description of key information

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification