Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Storage: Room temperature under nitrogen atmosphere (substance is hygroscopic)
Remarks on result:
no self ignition observed under the test conditions

No exothermic effects were determined. The wire mesh basket was empty after the measurement.

RFR 6634 does not undergo spontaneous combustion when tested according to EC A.16.

Conclusions:
RFR 6634 does not undergo spontaneous combustion when tested according to EC A.16.
Executive summary:

RFR 6634 is hygroscopic. The test substance was taken from the sample container in a nitrogen atmosphere.

The test was performed as stipulated in EC Test Procedure A.16 'Relative self-ignition temperature for solids'.

A certain volume of the substance under test was placed in an oven at room temperature; the temperature/time curve relating to conditions in the centre of the sample was recorded while the temperature of the oven was increased to 440 °C at a rate of 0.5 K/min. For the purpose of this test, the temperature of the oven at which the sample temperature reached 400 °C by self-heating is called the self-ignition temperature.

No exothermic effects were determined. The wire mesh basket was empty after the measurement.

RFR 6634 does not undergo spontaneous combustion when tested according to EC A.16.

Description of key information

RFR 6634 is hygroscopic. The test substance was taken from the sample container in a nitrogen atmosphere.

The test was performed as stipulated in EC Test Procedure A.16 'Relative self-ignition temperature for solids'.

A certain volume of the substance under test was placed in an oven at room temperature; the temperature/time curve relating to conditions in the centre of the sample was recorded while the temperature of the oven was increased to 440 °C at a rate of 0.5 K/min. For the purpose of this test, the temperature of the oven at which the sample temperature reached 400 °C by self-heating is called the self-ignition temperature.

No exothermic effects were determined. The wire mesh basket was empty after the measurement.

RFR 6634 does not undergo spontaneous combustion when tested according to EC A.16.

Key value for chemical safety assessment

Additional information