Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Short-term toxicity to fish

Currently viewing:

Administrative data

Endpoint:
short-term toxicity to fish
Type of information:
experimental study
Adequacy of study:
other information
Study period:
Jan 1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: well documented GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report date:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 203 (Fish, Acute Toxicity Test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
ZK 39.211 is Tamip monoamide

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
no

Test organisms

Test organisms (species):
Danio rerio (previous name: Brachydanio rerio)

Study design

Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
48 h

Results and discussion

Effect concentrations
Duration:
48 h
Dose descriptor:
LC50
Effect conc.:
> 10 g/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
mortality (fish)

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The LC50/48h of Tamip monoamid (ZK 39.211) to zebrafish is higher than 10 g/L.
Executive summary:

The compound was studied in a microbial growth test with the bacterium Pseudomonas putida according to DIN 38.412, L8. The test was performed under GLP. The microorganisms were incubated with the test substance over a period of 16 hours.The EC10 was higher than 10 g/L.