Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10/07/2009 – 13/07/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup apparatus
Flash point:
218 °C
Atm. press.:
101.3 kPa

Test Results test item:

Preparation : Sample heated to 80°C and allowed to cool to ambient temperature prior to analysis.

Apparatus : Pensky-Martens closed cup apparatus.

Barometric Pressure : 100.8 - 101.7 (kPa)

Results: Closed Cup Flash Point Temperature : 218°C @ 101.3 kPa

Interpretation of results:
GHS criteria not met
Conclusions:
Closed Cup Flash Point Temperature : 218°C @ 101.3 kPa.
Based on criteria mentioned in CLP regulation the chemical has a flashpoint > than 60 °C hence the test substance was considered to be non-flammable.

Description of key information

Closed Cup Flash Point Temperature : 218°C @ 101.3 kPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
218 °C

Additional information