Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 263-158-1 | CAS number: 61790-67-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 24 November 2015 to 6 September 2016
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- accepted calculation method
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Radiolabelling:
- no
- Test temperature:
- The test temperature was 25 °C
- Details on study design: HPLC method:
- HPLC EQUIPMENT AND EXPERIMENTAL CONDITIONS
Column: Zorbax CN 250 × 4.6 mm with the corresponding guard column
Mobile Phase: Methanol (55 %) and water (45 %), isocratic
Temperature: 25 °C
Flowrate: 1 mL/min
Injection volume: 25 µL
Detection: 210 nm
Run time: 60 minutes (formamide and acetanilide) to 60 minutes (test substance, DDT and mixed standard)
Three standards; formamide (for void volume), acetanilide (the lowest standard, log Koc of 1.25) and DDT (the highest standard, log Koc of 5.63) were used. Two identical runs were performed.
Due to the characteristics of the test substance a value for the adsorption coefficient could not be determined by experimental means. - Key result
- Type:
- log Koc
- Value:
- >= 2.409 - <= 13.021 dimensionless
- Remarks on result:
- other: KOCWIN-MCI method
- Key result
- Type:
- log Koc
- Value:
- >= 2.416 - <= 12.211 dimensionless
- Remarks on result:
- other: LKOW method
- Details on results (HPLC method):
- ESTIMATION OF THE ADSORPTION COEFFICIENT
Experimental Procedures
Consideration of the chemical structure and physical properties of the test material would lead to difficulties in determining a reliable adsorption coefficient.
A feasibility study was conducted to assess whether or not the HPLC simulation method could be used, as the test material exhibited a strong UV absorbance, albeit at 210 nm. A weak broad peak was observed either between that of formamide (the void marker) and acetanilide or before the formamide peak. This was not thought to be representative of the test material as it is a mixture and a quoted purity of 70 %. The representative chemical structure of the test material provided by the sponsor also indicate low UV chromophore group further supporting that HPLC-UV may not be suitable.
To confirm if the test substance was bound to the column, or not retained, the column was cleaned by first flushing with methanol for 1 hour followed by THF for 1 hour and then water for 1 hour. The system was then left equilibrating overnight with the mobile phase (55 % methanol:45 % water). With the initial methanol wash there was a large amount of contamination driven off. Nothing was recorded for the THF or water washes.
For the test material, the initial peak before the void marker was present but it also gave a number of peaks at 68 to 70 mins.
The peaks were further investigated to ascertain whether the peaks for the test material were retained on the frit or the column. This investigation revealed that the peaks at 68 and 70 mins were residual analytes that were not removed by the initial cleaning regime, as all subsequent injections of EXP150138 were clean. Under these conditions it can be assumed that the test material was not retained on the column.
It was concluded that on this basis the adsorption coefficient could not be estimated practically. Based on this it was decided calculate adsorption coefficient values using the Estimation Program Interface EPI ver. 4.1.
Calculated values
Calculated values for the log Koc were determined for each of the specified constituents of the test substance stated in information provided by the Sponsor.
The EPI ver 4.1 software used two different methods for calculating the adsorption coefficient, the KOCWIN-MCI and LKOW methods. The calculated values for log Koc from these two methods were as follows:
- KOCWIN-MCI calculated values ranged from 3.0072 for (E)-2-(nonenyl)butane-1,4-dioic acid to 4.4604 for (E)-2-(pentadecenyl)butane-1,4-dioic acid.
- The LKOW calculated values ranged from 1.9755 for (E)-2-(nonenyl)butane-1,4-dioic acid to 3.5243 for (E)-2-(pentadecenyl)butane-1,4-dioic acid. - Validity criteria fulfilled:
- yes
- Conclusions:
- The calculated estimation of the adsorption coefficient (Log Koc) ranged from 2.4095 to 13.0211(KOCWIN-MCI method) and 2.4161 to 12.2115 (LKOW method).
- Executive summary:
The adsorption coefficient of the test material was investigated in a study which was performed under GLP conditions and in accordance with the standardised guideline OECD 121 (Calculation).
Consideration of the chemical structure and physical properties of the test material would lead to difficulties in determining a reliable adsorption coefficient therefore a feasibility study was conducted to assess whether or not the HPLC simulation method could be used. Due to the characteristics of the test substance a value for the adsorption coefficient could not be determined by experimental means. It was therefore decided that estimated values would be calculated using appropriate software (Estimation Program Interface EPI ver. 4.1.)
The calculated estimation of the adsorption coefficient (Log Koc) ranged from 2.4095 to 13.0211(KOCWIN-MCI method) and 2.4161 to 12.2115 (LKOW method).
- Endpoint:
- adsorption / desorption: screening
- Remarks:
- Further information on adsorption/desorption
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- other:
Referenceopen allclose all
To test whether or not the test material was retained on the column, the following gradient was applied:
Time (minutes) |
Methanol (%) |
Water (%) |
0 |
55 |
45 |
60 |
55 |
45 |
70 |
100 |
0 |
130 |
100 |
0 |
140 |
55 |
45 |
150 |
55 |
45 |
Calculated Values for Adsorption Coefficient
Common name |
log Koc |
R = C14:0 |
2.4095 (KOCWIN-MCI) 2.4161 (LKOW) |
R = C16:0 |
2.9308 (KOCWIN-MCI) 2.9582 (LKOW) |
R = C16:1 |
2.9308 (KOCWIN-MCI) 2.8420 (LKOW) |
R = C18:0 |
3.4521 (KOCWIN-MCI) 3.5058 (LKOW) |
R = C18:1 |
3.4521 (KOCWIN-MCI) 3.3841(LKOW) |
R = C18:2 |
3.4521 (KOCWIN-MCI) 3.2679 (LKOW) |
R = C18:3 |
3.4521 (KOCWIN-MCI) 3.1462 (LKOW |
R1= C14:0 R2 = C18:0 |
7.3275 (KOCWIN-MCI) 7.4414 (LKOW) |
R1 = C14:0 R2 = C18:3 |
7.3275 (KOCWIN-MCI) 7.0819 (LKOW |
R1= C16:1 R2=C18:3 |
7.8488 (KOCWIN-MCI) 7.5078 (LKOW) |
R1 = C14:0 R2 = C16:0 R3 = C18:0 |
13.0211 (KOCWINMCI) 12.2115 (LKOW) |
R1 = C14:0 R2 = C16:1 R3 = C18:1 |
13.0211 (KOCWINMCI) 11.9737 (LKOW) |
R1 = C14:0 R2 = C16:1 R3 = C18:3 |
13.0211 (KOCWINMCI) 11.7358 (LKOW)
|
Description of key information
The calculated estimation of the adsorption coefficient (Log Koc) ranged from 2.4095 to 13.0211(KOCWIN-MCI method) and 2.4161 to 12.2115 (LKOW method).
Key value for chemical safety assessment
Additional information
The adsorption coefficient of the test material was investigated in a study which was performed under GLP conditions and in accordance with the standardised guideline OECD 121 (Calculation). The study was assigned a reliability score of 2 in accordance with the criteria for assessing data quality set forth by Klimisch et al. (1997).
Consideration of the chemical structure and physical properties of the test material would lead to difficulties in determining a reliable adsorption coefficient therefore a feasibility study was conducted to assess whether or not the HPLC simulation method could be used. Due to the characteristics of the test substance a value for the adsorption coefficient could not be determined by experimental means. It was therefore decided that estimated values would be calculated using appropriate software (Estimation Program Interface EPI ver. 4.1.)
The calculated estimation of the adsorption coefficient (Log Koc) ranged from 2.4095 to 13.0211(KOCWIN-MCI method) and 2.4161 to 12.2115 (LKOW method).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.