particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 20, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 59 (Dry Sieve test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
The test item was used in its initial form, without any pre-treatment.
Percentile:
D50
Mean:
150 - 210 µm
Remarks on result:
other: sieve test

Sieve Size (µm) Weight of Test Item (g) Material Passed Through Sieve Residue (Rx) % 
dx(g) Percentage (%)
710 10.0145 9.5704 95.57 4.43
500 10.0105 8.0335 80.25 19.75
300 10.0038 6.6942 66.92 33.08
210 10.0132 5.0647 50.58 49.42
150 10.0181 3.9757 39.69 60.31
45 10.0137 0.7652 7.64 92.36
Conclusions:
D50: between 150 - 210 µm
Executive summary:

The particle size distribution of the test item was determined as per CIPAC MT 59, “Dry Sieve test”.

The dry sieve test was carried out in single replicate. The sieve with 45 µm size retained more than 90 % of the particles; the sieve with 710 µm size, retained less than 10 % of the particles. The D50 was recorded between 150 - 210 µm.

Conclusion

D50: between 150 - 210 µm

Description of key information

D50: between 150 - 210 µm

Additional information

CIPAC MT 59 - sieve test