Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 28, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
adopted on 2 October 2012
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Type:
relative density
Density:
1.33
Temp.:
20 °C

DETERMINATION OF DENSITY OF TEST ITEM

Replication Number Weight of Test Item (g) Volume of Pycnometer (ml) Volume of Wetting Solution (ml) Density of Test Item (g/ml) SD (±) RSD (%)
1 40.6135 49.7652 19.34 1.3349 - -
2 40.9104 49.9681 19.2156 1.3303 - -

Mean

40.7619 49.8666 19.2778 1.3326 0.003 0.23

DETERMINATION OF VOLUME OF WETTING SOLUTION

Replication Number Weight of Empty Pycnometer (g) Weight of Pycnometer with Test Item and Wetting Solution (g) Weight of Pycnometer with Test Item (g) Weight of Test Item (g) Volume of Wetting Solution (ml)
1 30.4787 87.7149 71.0922 40.6135 19.3400
2 30.2272 87.6688 71.1376 40.9104 19.2156

Mean

30.3529 87.6918 71.1149 40.7619 19.2778

DETERMINATION OF WATER EQUIVALENT AND VOLUME OF PYCNOMETER AT 20 °C

Replication Number Weight of Empty Pycnometer Weight of Pycnometer with Water Water Equivalent Weight  Volume of the Pycnometer at 20 °C (ml)
1 30.4787 80.1444 49.6657 49.7652
2 30.2272 80.0954 49.8682 49.9681

Mean

30.3529 80.1199 49.7669 49.8666

DETERMINATION OF DENSITY OF WETTING SOLUTION

Replication Number Weight of Empty Pycnometer Weight of Pycnometer with Wetting Solution Weight of Wetting Solution (g) Volume of Pycnometer (ml) at 20 °C Density of Wetting Solution (g/ml)
1 30.4787 73.2517 42.7730 49.7652 0.8595
2 30.2272 73.2165 42.9893 49.9681 0.8603

Mean

30.3529 73.2341 42.8811 49.8666 0.8599
Conclusions:
Relative density: 1.33 at 20 °C
Executive summary:

The density of the test item was determined in accordance with OPPTS 830.7300 and OECD guideline No. 109.

The empty pyknometer, pyknometer with water, pyknometer with wetting solution, pyknometer with 2/3 of test item and pyknometer with 2/3 of test item and wetting solution were weighed and the weights were recorded to find out the water equivalent and the volume of the pyknometer. The density of the wetting solution, volume of wetting solution and density of the test item were calculated from the water equivalent and the volume of the pyknometer. The test was performed at 20 °C, under thermostatic conditions.

The density values resulted to be 1.3349 g/ml and 1.3303 g/ml for replicates R1 and R2, respectively; the calculated mean density value of the replicates was found to be 1.3326 ± 0.03 g/ml with 0.23 % of RSD.

The relative density resulted to be 1.33 at 20 °C.

Conclusion

Relative density: 1.33 at 20 °C

Description of key information

1.33 at 20 °C

Key value for chemical safety assessment

Relative density at 20C:
1.33

Additional information

OECD 109 - pycnometer method