Ames test

Diazokomponente Rot B was investigated using the Salmonella/microsome test according to OECD TG 471 using TA1535, TA100, TA1537, TA98 and TA 102 in the presence and in the absence of a metabolic activation system. Initially the plate incorporation methodology was used and concentrations up to and including 5000 µg/plate. Due to precipitation at 5000 µg/plate the following preincubation methodoloy was done with concentrations up to and including 2000 µg/tube showing predipitation from 1000 µg/tube onwareds. Evidence of mutagenic activity of Diazokomponente Rot B was not seen. No biologically relevant increase in the mutant count in comparison th the negative controls was observed in any of the strains tested with and without S9 -mix in the plate incorporation as well as in the preincubation modification under the experimental conditions applied. The positive controls were functional.

Therefore, Diazokomponente Rot B was considered to be non-mutagenic without and with S9-mix in the plate incorporation as well as in the preincubation modification of the Salmonella / microsme test (Bayer 2011).


Short description of key information:
Diazokomponente Rot B was considered to be non-mutagenic without and with S9-mix in the plate incorporation as well as in the preincubation modification of the Salmonella / microsme test (Bayer 2011).

Endpoint Conclusion: No adverse effect observed (negative)

Justification for classification or non-classification