Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

pH

Currently viewing:

Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Cinnamaldehyde
EC Number:
203-213-9
EC Name:
Cinnamaldehyde
Cas Number:
104-55-2
Molecular formula:
C9H8O
IUPAC Name:
3-phenylacrylaldehyde
Test material form:
other: Liquid
Details on test material:
- Name of test material (as cited in study report): Cinnamaldehyde
- Molecular formula (if other than submission substance):C9-H8-O
- Molecular weight (if other than submission substance):132.1612
- Smiles notation (if other than submission substance):c1(ccccc1)/C=C/C=O
- InChl (if other than submission substance):1S/C9H8O/c10-8-4-7-9-5-2-1-3-6-9/h1-8H/b7-4+
- Substance type: Organic
- Physical state: Liquid

Reagents

Reagent:
water

Results and discussion

pH value
Key result
pH value:
4.7
Temp.:
30 °C
Concentration:
1 vol%

Any other information on results incl. tables

TEST RESULTS

Method Details

Observations

Remarks if, any

Guideline

OECD 122

-

 

Method

 

pH Meter

-

Principle of method

 

 

 

 

 

 

 

A pH meter is essentially a voltmeter with high input impedance which measures the voltage of an electrode sensitive to the hydrogen ion concentration, relative to another electrode which exhibits a constant voltage.

 

 

 

-

Temperature of 1% w/v test solution

-

30 °C

pH (RESULT)

 

-

4.7

Inference

1.   

2.   

3.   

 

 

Acidic

Applicant's summary and conclusion

Conclusions:
The pH determination of test chemical was done as per the test guideline OECD 122. The mean pH of the test dispersion was determined with the help of digital pH meter. The mean pH was determine to be 4.7 at 30°C.
Executive summary:

The pH of test chemical was determined. Study was performed as per the test guideline OECD Guideline 122 (Determination of pH, Acidity and Alkalinity). The mean pH of the test dispersion was determined with the help of digital pH meter. The mean pH was determine to be 4.7 at 30°C. Thus, test chemical was considered to be acidic in nature.