Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
no data
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Results sufficiently described and documented.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Principles of method if other than guideline:
The particle size distribution of a sample of the test substance was performed using laser diffraction. A Malvern Master Sizer S was used. The sample was dispersed in deionized water and the solution was stirred mechanically and ultrasonically to guarantee homogenous dispersion of the particles.
GLP compliance:
not specified
Type of distribution:
volumetric distribution

Test material

Constituent 1
Reference substance name:
nickel (II) oxalate dihydrate
IUPAC Name:
nickel (II) oxalate dihydrate
Constituent 2
Reference substance name:
6018-94-6
Cas Number:
6018-94-6
IUPAC Name:
6018-94-6
Details on test material:
- Name of test material (as cited in study report): nickel oxalate dihydrate
- Molecular formula (if other than submission substance): NiC2O4.2H2O
- Molecular weight (if other than submission substance): 182.7 g/mol
- Physical state: powder
- Analytical purity: no data
- Lot/batch No.: no data
- Expiration date of the lot/batch: no data
- Stability under test conditions: no data
- Storage condition of test material: at room temperature in the dark

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
11.72 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
other: D25
Mean:
> 23.62 - < 26.04 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
D50
Mean:
37.02 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
other: D75
Mean:
ca. 51.62 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
D90
Mean:
66.25 µm
Remarks on result:
other: The standard deviation was not provided.

Applicant's summary and conclusion

Conclusions:
The particle size distribution of nickel oxalate powder was determined using a volumetric method. The particle diameters of D10%, D50% and D90% were 11.72, 37.02 and 66.25 µm, respectively.