Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Batch: 2018060002
pH: 7.60
moisture content: 30.29%
Remarks on result:
no flash point according to standard method
Interpretation of results:
GHS criteria not met
Conclusions:
The test item RICOIL EN has no flash point up to a temperature of 200 °C according to Regulation (EC) No 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2016) and DIN EN ISO 3679 (2015), respectively.

According to the results of the test on the flash point, the test item is classified as follows:
UN Transport Regulation: With no measured flash point up to a temperature of 200 °C, the test item does not have to be classified as Flammable Liquid of Class 3.
Attention: Under the transport regulation special rules apply to viscous compounds.

GHS (CLP Regulation (EC) No 1272/2008 Annex I: 2.6): With no measured flash point up to a temperature of 200 °C, the test item does not have to be classified as Flammable Liquid.
Executive summary:

The test item RICOIL EN has no flash point up to a temperature of 200 °C according to Regulation (EC) No 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2016) and DIN EN ISO 3679 (2015), respectively.

According to the results of the test on the flash point, the test item is classified as follows:

UN Transport Regulation: With no measured flash point up to a temperature of 200 °C, the test item does not have to be classified as Flammable Liquid of Class 3.

Attention: Under the transport regulation special rules apply to viscous compounds.

GHS (CLP Regulation (EC) No 1272/2008 Annex I: 2.6): With no measured flash point up to a temperature of 200 °C, the test item does not have to be classified as Flammable Liquid.

Description of key information

The test item RICOIL EN has no flash point up to a temperature of 200 °C according to Regulation (EC) No 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2016) and DIN EN ISO 3679 (2015), respectively.

According to the results of the test on the flash point, the test item is classified as follows:

UN Transport Regulation: With no measured flash point up to a temperature of 200 °C, the test item does not have to be classified as Flammable Liquid of Class 3.

Attention: Under the transport regulation special rules apply to viscous compounds.

GHS (CLP Regulation (EC) No 1272/2008 Annex I: 2.6): With no measured flash point up to a temperature of 200 °C, the test item does not have to be classified as Flammable Liquid.

Key value for chemical safety assessment

Additional information