Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
- Purity: 100%
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In contact with the flame of the gas burner the test item melted and turned into a light brown residue. White smoke was observed. After removal of the ignition source, no propagation of combustion of the test item was observed.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item is considered not flammable.
Executive summary:

A preliminary screening test was performed for the determination of the flammability of the test item in accordance with method UN N.1.No propagation of combustion of the test item along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item isconsidered ‘not flammable’.

Description of key information

Method UN N.1

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test substance is not flammable and is not classified according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.