Administrative data

Endpoint:
melting point/freezing point
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Thermogravimetric analysis or thermal gravimetric analysis (TGA)
GLP compliance:
yes
Type of method:
thermal analysis
Remarks:
thermal gravimetric analysis (TGA)

Test material

Specific details on test material used for the study:
Name magnesium hexafluorosilicon hexahydrate
Batch no. msk 16949658
Appearance white powder
Composition mono constituent

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
124 °C
Decomposition:
yes
Remarks:
melting at 124°C, followed by two decomposition reactions at 136°C and 138°C.
Decomp. temp.:
ca. 136 °C

Applicant's summary and conclusion

Conclusions:
The thermal stability of the test item was screened, by conducting a TGA in a temperature range between 40°C and 950°C.
The analysis of the data and the corresponding curve show, that the sample of the test item is melting at 124°C, followed by two decomposition reactions at 136°C and 138°C.