Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch: 703709
Purity: 100 %
CoA: 2017-02-15
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
Since no independent burning or glowing over the length of the pile was observed, the test item does not have to be classified as "flammable solid".
Executive summary:

The flammability of IPDI-Uron was determined according to EC method A.10

No independent burning or glowing over the length of the pile was observed in the preliminary test.

Since no independent burning or glowing over the length of the pile was observed, the test item does not have to be classified as "flammable solid".

Description of key information

Substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

An OECD guideline study showed the result: No independend burning or glowing of the substance.