Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidance followed, no GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Viscosity
Temp.:
other: 80.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 2.1

Any other information on results incl. tables

Standard deviation: 0.0 mm2.s-1

Average kinematic viscosity: 2.1 mm2.s-1 at 80 °C