Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-04-18 to 2008-05-20
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary method

Test material

Constituent 1
Reference substance name:
Reaction product of Acid Yellow 42, Acid Black 2 and Basic Violet 1
IUPAC Name:
Reaction product of Acid Yellow 42, Acid Black 2 and Basic Violet 1
Constituent 2
Reference substance name:
Acid Yellow 42: 6375-55-9
IUPAC Name:
Acid Yellow 42: 6375-55-9
Constituent 3
Reference substance name:
Acid Black 2: reaction product of 8005-03-6 and 68510-98-5
IUPAC Name:
Acid Black 2: reaction product of 8005-03-6 and 68510-98-5
Constituent 4
Reference substance name:
Basic Violet 1: 8004-87-3
IUPAC Name:
Basic Violet 1: 8004-87-3
Details on test material:
- Name of test material: Reaction product of Acid Yellow 42, Acid Black 2 and Basic Violet 1
- Lot/batch No.: 2008041541
- Expiration date of the lot/batch: 2010-01-31
- Stability under test conditions: see expiry date
- Storage condition of test material: store cool and dry
- Analytical purity: 100 % (96.8 %, UVCB substance)

Results and discussion

Melting / freezing pointopen allclose all
Decomposition:
yes
Decomp. temp.:
213 °C
Remarks on result:
other: rounded mean of measured temperatures, no liquid phase observed up to 400 °C
Decomp. temp.:
>= 212.4 - <= 212.7 °C
Remarks on result:
other: the test item decomposed in a range from 212.4 - 212.7 °C

Applicant's summary and conclusion

Conclusions:
No melting point was determined. The test item decomposed at a rounded mean temperature of 213 °C, i.e. 486 K. No liquid phase was observed up to 400 °C.
Executive summary: