Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: screening tests
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP study according to old methods. Study report which meets basic scientific principles.

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1993
Report date:
1992

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 84/449/EEC C.10
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

BOD5 / COD results

BOD5 / COD
Parameter:
COD
Value:
2.1 g O2/g test mat.

Any other information on results incl. tables

Comments:

THE WATER SOLUBILITY OF THE SUBSTANCE TEST IS LOWER THAN 3×10 -7 g/L; ATTEMPS TO DEVELOPE MORE SENSITIVE ANALYTICAL METHOD HAD BEEN UNSUCCESFUL