Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP study according to old methods. Study report which meets basic scientific principles.

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1993
Report date:
1992

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 88/449/EEC A.4
Type of method:
other: no data

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
50 °C
Vapour pressure:
< 0 Pa
Remarks on result:
other: First vapour pressure
Temp.:
25 °C
Vapour pressure:
< 0 Pa
Remarks on result:
other: Estimated vapour pressure value
Temp.:
200 °C
Vapour pressure:
1.27 Pa
Remarks on result:
other: Second vapour pressure

Applicant's summary and conclusion