Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Acute Toxicity: inhalation

Currently viewing:

Administrative data

Endpoint:
acute toxicity: inhalation
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: only orientating information about the inhalation hazard

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1963
Report date:
1963

Materials and methods

Principles of method if other than guideline:
according to BASF-internal standard
GLP compliance:
no
Test type:
other: inhalation hazard test

Test material

Constituent 1
Chemical structure
Reference substance name:
1,6-dichlorohexane
EC Number:
218-491-7
EC Name:
1,6-dichlorohexane
Cas Number:
2163-00-0
Molecular formula:
C6H12Cl2
IUPAC Name:
1,6-dichlorohexane
Test material form:
other: liquid

Test animals

Species:
rat
Strain:
not specified
Sex:
male/female

Administration / exposure

Route of administration:
inhalation: vapour
Type of inhalation exposure:
other: inhalation hazard test
Details on inhalation exposure:
Inhalation of an atmosphere saturated with vapour. For saturation, air was conducted through a layer of about 5 cm of the product.
Duration of exposure:
8 h
No. of animals per sex per dose:
12
Control animals:
no

Results and discussion

Mortality:
none
Clinical signs:
other: none
Other findings:
Necropsy findings: No abnormalities detected.

Applicant's summary and conclusion

Conclusions:
1,6-Dichlorohexane was tested in 12 animals. The rats were exposed to an atmosphere saturated with vapour for about 8 hours. For saturation, air was conducted through a layer of about 5 cm of the product. No mortality and no clinical signs were observed.