Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The melting point / melting range is determined by differential scanning calorimetry (DSC). The test
item and the reference are heated up from the starting temperature to the final temperature at a
constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for
the test item and as empty reference crucible. The quantity of heat absorbed or released is measured
and recorded.















Starting
temperature (ºC)
Finaltest
temperature (ºC)
Temperature range (ºC)
25500

210 - 490
(exothermal)




The test item had no melting point at atmospheric conditions. Decomposition started at approx. 300ºC.

 

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
300 °C

Additional information