Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Density
Administrative data
Link to relevant study record(s)
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.977 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9769 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9769 Kg/L at 15ºC.
- Endpoint:
- density, other
- Remarks:
- density
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Not stated
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP status not known, guideline study, available as unpublished report, limitations in design and/or reporting but otherwise adequate for assessment.
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D4052
- Deviations:
- not specified
- GLP compliance:
- not specified
- Type of method:
- other: Not specified
- Key result
- Type:
- density
- Density:
- >= 0.926 - <= 1 other: no units reported
- Temp.:
- 20 °C
- Conclusions:
- The density of the substance CAS no. 68477-54-3 was measured to be 0.926 to 1.000 (no units reported) at 20ºC.
- Executive summary:
Data was received from the company reporting density. This data is considered reliable and suitable for use. The density of the substance CAS no. 68477-54-3 was measured to be 0.926 to 1.000 (no units reported) at 20ºC.
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.93 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9301 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9301 Kg/L at 15ºC.
- Endpoint:
- density, other
- Remarks:
- density
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP status not known, guideline study, available as unpublished report, limitations in design and/or reporting but otherwise adequate for assessment.
- Qualifier:
- according to guideline
- Guideline:
- other: DIN 51757
- GLP compliance:
- not specified
- Type of method:
- other: Not stated
- Key result
- Type:
- density
- Density:
- >= 0.902 - <= 0.952 other: g/ml
- Temp.:
- 20 °C
- Remarks on result:
- other: Result for RÜTGERS 02, RÜTGERS 04, RÜTGERS 05, RÜTGERS 06, RÜTGERS 07 and RÜTGERS 08
- Conclusions:
- The density of the substance CAS no. 68477-54-3 was measured to be 0.902 g/mL to 0.952 g/mL at 20ºC.
- Executive summary:
Data was received from the company reporting density. This data is considered reliable and suitable for use. The density of the substance CAS no. 68477-54-3 was measured to be 0.902 g/mL to 0.952 g/mL at 20ºC.
- Endpoint:
- relative density
- Remarks:
- Other density types indicated: density
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 30/04/2007
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP, guideline study, available as unpublished report, acceptable with restrictions
- Principles of method if other than guideline:
- Density according to ASTM D 1298
Relative density at 60/60°C according to ASTM D 1298/D 1250 - GLP compliance:
- yes (incl. QA statement)
- Type of method:
- other: no data
- Key result
- Type:
- relative density
- Density:
- 0.894
- Temp.:
- 60 °F
- Key result
- Type:
- density
- Density:
- 0.893 other: kg/l
- Temp.:
- 15 °C
- Conclusions:
- The relative density of 68477-54-3 is reported to be 0.8936 at 60°F.
- Executive summary:
This is a guideline study considered adequate for assessment. The relative density of 68477-54-3 is reported to be 0.8936 at 60°F.
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.972 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9715 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9715 Kg/L at 15ºC.
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.914 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9138 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9138 Kg/L at 15ºC.
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.98 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9799 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9799 Kg/L at 15ºC.
- Endpoint:
- relative density
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 30/04/2007
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP, guideline study, available as unpublished report, acceptable with restrictions
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 109 (Density of Liquids and Solids)
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- relative density
- Density:
- 0.94 g/cm³
- Temp.:
- 20 °C
- Conclusions:
- Relative density of C9 - Schnitt (Bl 14002) is D420 = 0.9434 g/cm3.
- Executive summary:
This is a GLP compliant, guideline study considered adequate for assessment. Relative density of C9 - Schnitt (Bl 14002) is D420 = 0.9434 g/cm3.
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.954 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9542 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9542 Kg/L at 15ºC.
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
- Principles of method if other than guideline:
- This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
- GLP compliance:
- no
- Type of method:
- oscillating densitimeter
- Key result
- Type:
- density
- Density:
- 0.973 other: kg/L
- Temp.:
- 15 °C
- Conclusions:
- The density of this substance is 0.9726 Kg/L at 15ºC.
- Executive summary:
The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9726 Kg/L at 15ºC.
- Endpoint:
- density, other
- Remarks:
- other: not reported
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP unknown, guideline study, available as statement letter from registrant, acceptable with restrictions
- Qualifier:
- according to guideline
- Guideline:
- other: DIN 51757
- GLP compliance:
- not specified
- Type of method:
- other: not reported
- Key result
- Type:
- other: not reported
- Density:
- 0.972 other: g/ml
- Temp.:
- 20 °C
- Conclusions:
- The density of Cas No 101316 -62-5 was determined as 0.972 g/mL at 20 Degs C.
- Executive summary:
Information was provided by individual companies in the form of a letter stating the relevant information. The letter was submitted in company’s headed paper and signed by the individual responsible for the area of work. Given that the companies have practical expertise in handling the substance/stream this was deemed to be acceptable information. The density of Cas No 101316-62-5 was determined as 0.972 g/mL at 20 Degrees C.
- Endpoint:
- density, other
- Remarks:
- other: not reported
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: GLP unknown, guideline study, available as statement letter from registrant, acceptable with restrictions
- Qualifier:
- according to guideline
- Guideline:
- other: DIN 51757
- GLP compliance:
- not specified
- Type of method:
- other: not reported
- Key result
- Type:
- other: not reported
- Density:
- 0.96 other: not reported
- Temp.:
- 20 °C
- Conclusions:
- The density of Cas No 101316-62-5 was determined as 0.963 at 20 Degs C.
- Executive summary:
Information was provided by individual companies in the form of a letter stating the relevant information. The letter was submitted in company’s headed paper and signed by the individual responsible for the area of work. Given that the companies have practical expertise in handling the substance/stream this was deemed to be acceptable information. The density of Cas No 101316-62-5 was determined as 0.963 at 20 Degrees C.
Referenceopen allclose all
2 determinations
no further details
no further details
Description of key information
Density data are available for 7 streams (13 studies) within this category ranging from 0.894 to 1.000.
Key value for chemical safety assessment
- Relative density at 20C:
- 0.945
Additional information
The density values for streams in this category have been taken from lead-registrant data, proprietary data and certificates of analysis. The data will be read across to all category members.
Lead-registrant data (Intertek, 2018):
EC 266 -013 -0 (CAS#65996-79 -4): 0.9769 Kg/L;
EC 270 -737 -2 (CAS#68477-54-3): 0.9301 Kg/L;
EC 270 -790 -1 (CAS#68478-10-4): 0.9715 Kg/L;
EC 271 -138 -9 (CAS#68516-20-1): 0.9138 Kg/L;
EC 271 -213 -6 (CAS#68526-56-7): 0.9799 Kg/L;
EC 305 -586 -4 (CAS#94733-07-0): 0.9542 Kg/L;
EC 309 -867 -2 (CAS#101316-62-5): 0.9726 Kg/L.
Proprietary data:
CAS# 94733-07-0: 0.94 g/cm3 at 20°C (BASF, 2007a);
CAS# 101316-62-5: 0.96 (no unit) and 0.972 g/mL at 20°C (TS&D Rutgers Germany 2010b, c);
CAS# 68477-54-3 range 0.902 - 0.952 g/mL at 20°C (RÜTGERS 2010a, 2010b, 2010c), 0.926 - 1.000 (no units reported) (Dow Benelux 2010b), 0.8936 at 15.6°C (SIBUR, 2009).
The mean of the density values for the category is 0.945 (unitless) and this value has been used to complete the 'key value for the safety assessment'.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.