Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01/03/2019 – 04/03/2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Atm. press.:
101.325 kPa
Decomposition:
yes
Decomp. temp.:
ca. 150 °C

Comments

An 18% mass loss was recorded following heating the sample to 500°C.

The full profile for the screening test is provided in the full report's graph.

Conclusions:
The exact boiling point of 4,4'-isopropylidenediphenol, reaction products with 1-chloro-2,3-epoxypropane, mono, di and triesters with acrylic acid was not determined because the substance begins to decompose at around 150°C.
Executive summary:

Boiling point testing was performed on 4,4'-Isopropylidenediphenol, reaction products with 1-chloro-2,3-epoxypropane, mono, di and triesters with acrylic acid in accordance with the EU Method A.2. The exact boiling point was unable to be determined due to the substance beginning to decompose at around 150°C.

Description of key information

Boiling point testing was performed on 4,4'-Isopropylidenediphenol, reaction products with 1-chloro-2,3-epoxypropane, mono, di and triesters with acrylic acid in accordance with the EU Method A.2. The exact boiling point was unable to be determined due to the substance beginning to decompose at around 150°C.

Key value for chemical safety assessment

Additional information