Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Data waiving:
other justification
Justification for data waiving:
other:
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland Open Cup Tester
Remarks:
see "Overall remarks"
Flash point:
314 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: Pressure not reported. Ambient conditions (ca. 1013 hPa) can be assumed as the test was conducted using an open cup system.

Description of key information

Flash point > 200.0 °C

Key value for chemical safety assessment

Additional information

The flash-point of the test substance was determined by Cleveland open cup method according to DIN EN ISO 2592. Since the measured flash-point (314 °C) is far above the classification limit and above 200 °C, the open-cup method is used to support an estimated flash point > 200 °C.