Administrative data

Endpoint:
boiling point
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a solid which melts above 300°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1987
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
not specified
Type of method:
other: Metal black apparatus
Specific details on test material used for the study:
- GLP sample 706
Key result
Melting / freezing pt.:
> 300 °C
Atm. press.:
101.3 kPa
Decomposition:
no
Conclusions:
Under the study conditions, the melting point was determined to be >300˚C at 101.3 kPa.
Executive summary:

A study was conducted to determine the melting point of the substance according to EU Guideline A.1. ( metal black apparatus). Under the study conditions, the melting point was determined to be >300˚C at 101.3 kPa (Macnab, 1987).