Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
non-equilibrium method closed cup
Key result
Flash point:
> 200 °C
Atm. press.:
96.2 kPa
Remarks on result:
other: No flash point was detected up to 200 °C in all of the three replicate measurements.
Interpretation of results:
GHS criteria not met

Description of key information

> 200 °C at 96000 Pa (EU A.9)

Key value for chemical safety assessment

Additional information

No flash point was detected up to 200 °C.