Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 January 2009 to 07 February 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of inspection: 19 August 2008; Date of signature: 04 March 2009
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sponsor's identification : H-CB sodium salt
Description : blue solid
Purity : 94.8%
Lot number : MB-2
Date received : 04 December 2008
Storage conditions : room temperature in the dark

Results and discussion

Density
Type:
relative density
Density:
1.74
Temp.:
20 °C

Any other information on results incl. tables

Calibration

The pressure readings (P1and P2) and the calculated volume for the calibration ball are shown in the following table:

 

Table 1

 

Determination

P1

P2

Volume (cm3)

Certified Volume (cm3)

Tolerance (cm3)

A

17.031

8.430

56.4

56.6

+/- 0.5

B

17.535

8.679

56.4

56.6

+/- 0.5

 

Sample

The pressure readings, calculated volumes and density values obtained for the test material are shown in the following table:

 

Table 2

 

Determination

P1

P2

Volume (cm3)

Density (kg/m3)

A

17.521

7.499

27.7

1.74 x 103

B

17.113

7.119

21.5

1.74 x 103

 

Temperature:              20.0 +/- 0.5oC

Mean density:             1.74 x 103kg/m3

Relative density:         1.74

Applicant's summary and conclusion

Conclusions:
The relative density of the test material has been determined to be 1.74 at 20.0 +/- 0.5 Deg C
Executive summary:

1.74 at 20.0 +/- 0.5 Deg C, using a gas comparison pycnometer, result was obtained according to Method A3 Relative Density of Commission Regulation (EC) No 440/2008 of 30 May 2008.