Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1988-11-30
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
yes
Remarks:
It was used a settled sludge. The substance was not dissolved but distributed in the test medium. The sludge concentration in the test bottles was 2 g/L instead of 1.4 - 1.8 g/L.
GLP compliance:
no
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: stock solution: 20.8 rsp. 20.2 mg of the test substance were weighed and added to the test medium. The volume was adjusted to 200 mL with bidistilled water and aerated for 3 hours.
- Evidence of undissolved material (e.g. precipitate, surface film, etc):
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Preparation of inoculum for exposure: according to the method described in the guideline. Instead of a centrifuged sludge a settled sludge was used.
- Initial biomass concentration: 2.0 g/L
Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h
Post exposure observation period:
none
Test temperature:
20 ± 2 °C
pH:
not determined
Nominal and measured concentrations:
104 and 101 mg/L (nominal)
Details on test conditions:
TEST SYSTEM
- Test vessel: BOD flasks with gas inlet
- Material, size, headspace, fill volume: 250 mL (size)
- Aeration: none during the test
- No. of vessels per concentration: 1
- No. of vessels per control: 1
- Biomass loading rate: 2 g/L

TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: dechlorinated drinking water
16 g Peptone
11 g Meat extract
3.0 g Urea
0.7 g NaCl
0.4 g CaCl2 • 2 H2O
0.2 g MgSO4 • 7 H2O
2.8 g K2HPO4
per liter dechlorinated drinking water

OTHER TEST CONDITIONS
- Adjustment of pH: none

EFFECT PARAMETERS MEASURED: Oxygen consumption per hour in mg/liter

TEST CONCENTRATIONS
- Spacing factor for test concentrations: single dose in duplicate
- Justification for using less concentrations than requested by guideline: expected low toxicity of the test substance
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorophenol at 32, 10, and 3.2 mg/L
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
> 100 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Remarks:
Graphically determined
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 h
Dose descriptor:
other: IC20
Effect conc.:
> 100 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Remarks:
Graphically determined
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 h
Dose descriptor:
other: IC80
Effect conc.:
> 100 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Remarks:
Graphically determined
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Details on results:
- Any observations that might cause a difference between measured and nominal values: none reported
- Effect concentrations exceeding solubility of substance in test medium: none reported
Results with reference substance (positive control):
- Results with reference substance valid: yes
- Relevant effect levels: IC50 12 mg/L, graphically determined

Description of key information

The inhibition of the degradation activity of activated sludge is not anticipated when tris(2,4-di-tert-butylphenyl)phosphite introduced in appropriate low concentrations.

Key value for chemical safety assessment

Additional information

The toxicity of tris(2,4-di-tert-butylphenyl)phosphite on microorganisms was tested in a limit test performed according to OECD guideline 209 [Ciba, 1988]. At the test concentration of about 100 mg/L no effect on the respiration rate of activated domestic sludge was measured.