Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Adsorption / desorption

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals. The study was performed at a temperature of 23°C and pH 4-10, respectively. . Each of the reference substance and test substance were were analysed by Modular HPLC system with UV/Vis detector. Acetonitrile was used as a mobile phase. 5µl of test chemical was introduced in the column. The dead time of the HPLC system was measure with formamide. The reference substance used for the study were formamide, methyl benzoate, naphthalene, methiocarb, pyrazophos, alpha-endosulfan, diclofo-methyl and DDT, respectively. The Log Koc value of test chemical was determined to be > 5.63 dimensionless at 23°C. This log Koc value indicates that the substance has a very strong sorption to soil and sediment and therefore have negligible migration potential to ground water.

Additional information

Adsorption / desorption

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals. The study was performed at a temperature of 23°C and pH 4-10, respectively. . Each of the reference substance and test substance were were analysed by Modular HPLC system with UV/Vis detector. Acetonitrile was used as a mobile phase. 5µl of test chemical was introduced in the column. The dead time of the HPLC system was measure with formamide. The reference substance used for the study were formamide, methyl benzoate, naphthalene, methiocarb, pyrazophos, alpha-endosulfan, diclofo-methyl and DDT, respectively. The Log Koc value of test chemical was determined to be > 5.63 dimensionless at 23°C. This log Koc value indicates that the substance has a very strong sorption to soil and sediment and therefore have negligible migration potential to ground water.