Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
GLP compliance:
no
Type of method:
pycnometer method

Test material

Constituent 1
Reference substance name:
DONA
IUPAC Name:
DONA
Details on test material:
- Name of test material (as cited in study report): PF-13 Acid
- Lot/batch no.: 144560-059-5

Results and discussion

Density
Type:
relative density
Density:
1.81
Temp.:
23 °C

Any other information on results incl. tables

The test was carried out at a temperature of 23 °C with a pycnometer. The relative density of the test item at 23 °C is the quotient of the weights of the content of the test item and of the water content.

Applicant's summary and conclusion

Conclusions:
The relative density of DONA is 1.81 at 23 °C.
Executive summary:

The relative density of DONA is 1.81 at 23 °C determined using a pycnometer method. No further information on this report is available. The reliability of this data cannot be established.