Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 12th, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method. Test substance is adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
22.3
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
10.9

Results of duplicate measurement at two different temperatures:

No

Temperature : 20°C

Temperature : 40°C

Viscosity (mPa.s)

1

22.3

10.9

2

22.3

10.9

Average

22.3

10.9

Conclusions:
The viscosity of test item was determined according to OECD 114 guideline, using a rotational viscometer.
The viscosity of test item was 22.3 mPa.s at 20°C and 10.9 mPa.s at 40°C for a speed of 10 rpm.
Executive summary:

The viscosity of test item was determined according to OECD 114 guideline, using a rotational viscometer.

The viscosity of test item was 22.3 mPa.s at 20°C and 10.9 mPa.s at 40°C for a speed of 10 rpm.

Description of key information

The viscosity of test item was 22.3 mPa.s at 20°C and 10.9 mPa.s at 40°C for a speed of 10 rpm.

Key value for chemical safety assessment

Viscosity:
22.3 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

A fully reliable experimental study, conducted according to OECD 114 guideline is available.

It is considered as a key study, and the result is retained as key data.