Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 january 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
no guideline required
Principles of method if other than guideline:
The prediction was carried out using a procedure designed to be compatible with Regulation (EC) No 1272/2008 of 16 December 2008 on Classification labelling and Packaging of Substances and Mixtures.
The structure is assessed for the content of oxygen, fluorine or chlorine, if these elements are present, further assessment is carried out to establish if the fluorine, chlorine and/or oxygen are chemically bonded only to hydrogen and carbon.
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Identification: Semicarbazide hydrochloride
CAS No: 563-41-7
Appearance/Physical state: White powder
Batch: 55507861
Purity: 99.3%
Expiry date: 04 January 2020
Storage conditions: Room temperature in the dark
Contact with:
other: none
Key result
Sample tested:
other: prediction
Parameter:
preliminary test
Result:
0 other: no oxiding properties
Remarks on result:
other: no oxidizing properties

None

Interpretation of results:
other: No oxidizing properties
Conclusions:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.
Executive summary:

Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.

Description of key information

Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification