Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study report did not specify whether a guideline was followed. The study was not conducted in accord with GLP guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
Oscillating piston method
GLP compliance:
no
Type of method:
other: Oscillating piston

Test material

Constituent 1
Reference substance name:
DONA
IUPAC Name:
DONA
Details on test material:
- Name of test material (as cited in study report): 144560-059-5

Results and discussion

Viscosity
Temp.:
other: 25.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
7.615

Applicant's summary and conclusion

Conclusions:
The viscosity of DONA is 7.615 mPa∙s at 25.0 °C
Executive summary:

The viscosity of DONA was measured with a Cambridge viscometer. The viscosity of the test substance measured at 25.0 °C is 7.615 mPa∙s. Although the viscometer used in this study is compliant with ASTM D-7483-13, and Cambridge company specifications indicate correlation to ASTM D445 standards, it is unknown if this study followed an ISO, ASTM, or OECD guideline, as well as whether the study was conducted in accord with GLP guidelines. Therefore the study is classified reliable with restrictions.