Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
OECD 113, Screening test, GLP. Study according to relevant guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Deviations:
no
Principles of method if other than guideline:
Method: Differential scanning calorimetry (DSC, screening test, thermal stability)
Test conditions: Standard material: aluminium oxide
Constant heating rate: 3 K/min
Defined atmosphere: nitrogen
Amount of sample: 9 mg
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Exo-1,7,7-trimethylbicyclo[2.2.1]hept-2-yl methacrylate
EC Number:
231-403-1
EC Name:
Exo-1,7,7-trimethylbicyclo[2.2.1]hept-2-yl methacrylate
Cas Number:
7534-94-3
Molecular formula:
C14H22O2
IUPAC Name:
1,7,7-trimethylbicyclo[2.2.1]hept-2-yl methacrylate
Test material form:
liquid

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
>= 25 - <= 330 °C
Remarks on result:
other: Isobornyl methacrylate showed no exothermal effects in the temperature range of 25 - 330 °C.
Sublimation:
not determined
Transformation products:
not measured

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Applicant's summary and conclusion

Conclusions:
The DSC-measurement according to OECD 113 in a closed glass crucible showed no exothermal effects in the temperature range of 25 - 330 °C.
Executive summary:

The DSC-measurement according to OECD 113 in a closed glass crucible showed no exothermal effects in the temperature range of 25 - 330 °C.