Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 December 2013 - 23 December 2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study performed in accordance with sound scientific principles, with incomplete reporting or methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
The flash point of the test material was determined using the equilibrium closed cup method using APTEM ABEL IP-170 apparatus.
GLP compliance:
not specified
Type of method:
equilibrium method closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
2-ethoxy-4,6-difluoropyrimidine
EC Number:
692-762-1
Cas Number:
166524-65-8
Molecular formula:
C6H6F2N2O
IUPAC Name:
2-ethoxy-4,6-difluoropyrimidine
Test material form:
not specified
Details on test material:
- Name of test material (as cited in study report): DFEP
- Lot/batch No.: GRN 30153
- Date sampled: 12 March 2013

Results and discussion

Flash pointopen allclose all
Flash point:
> 69 °C
Remarks on result:
other: Test No. 1 (pressure was not reported)
Flash point:
> 69 °C
Remarks on result:
other: Test No. 2 (pressure was not reported)

Any other information on results incl. tables

The flash point of the test material was determined to be > 69.0 °C.

Applicant's summary and conclusion

Conclusions:
Under the conditions of the test, the flash point of the test material was determined to be > 69.0 °C.
Executive summary:

The flash point of the test material was determined using closed cup flash point apparatus APTEM ABEL IP-170. Under the conditions of the test, the flash point of the test material was determined to be > 69.0 °C and therefore does not require classification as a flammable liquid.