Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-701-1 | CAS number: 7691-02-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Hydrolysis
Administrative data
Link to relevant study record(s)
- Endpoint:
- hydrolysis
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2006
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 111 (Hydrolysis as a Function of pH)
- GLP compliance:
- yes
- Analytical monitoring:
- no
- Details on sampling:
- Not applicable.
- Buffers:
- Buffer solutions were prepared to known final volumes in polypropylene volumetric flasks with Milli-Q water. If necessary, final pH adjustments were made by dropwise addition of 1M lithium hydroxide solution. Prior to use, all buffer solutions were sparged with helium gas for a minimum of 5 min to exclude oxygen and were sterilized using a Nalgene sterile filtration unit with a 0.20 µM cellulose nitrate (CN) membrane.
- pH: Target: 4.0; Measured: 4.01
- Type and final molarity of buffer: Acetic Acid/Lithium Hydroxide, 0.05M
- Composition of buffer: 50mL 1 M Acetic Acid solution, 7.47 mL 1M Lithium Hydroxide solution. Total volume 1000 mL.
- pH: Target: 7.0; Measured: 7.01
- Type and final molarity of buffer: Citric acid/Lithium Hydroxide, 0.05M
- Composition of buffer: 50mL 1 M Citric acid solution, 140 mL 1M Lithium Hydroxide solution. Total volume 1000 mL.
- pH: Target: 9.0; Measured: 8.99
- Type and final molarity of buffer: Boric acid/Lithium hydroxide, 0.30M
- Composition of buffer: 125 mL 0.1 M boric acid solution, 6.8 mL 1M Lithium Hydroxide solution. Total volume 1000 mL. - Estimation method (if used):
- Not applicable.
- Details on test conditions:
- TEST SYSTEM
- Type, material and volume of test flasks, other equipment used: The test vessels were uniquely labelled 100 mL clear glass beakers. Parafilm was used to maintain a closed system.
- Sterilisation method: Sterility tests were not conducted since they were deemed unnecessary due to the rapid hydrolysis of the test substance. Similarly, non-sterilized labware were used.
- Measures taken to avoid photolytic effects: Not applicable.
- Measures to exclude oxygen: Not applicable.
- Details on test procedure for unstable compounds: The test substance is unstable with respect to moisture. To prevent exposure of the test substance to moisture in air, the test substance solution was prepared in a nitrogen purged glove bag. The test substance solution was contained in 2 x 20 mL glass vials having septum lined open-top caps. The test substance containers were stored over Drierite in a secondary air tight container in a freezer when not in use.
- Details of traps for volatile, if any: None
- If no traps were used, is the test system closed/open: Closed
- Is there any indication of the test material adsorbing to the walls of the test apparatus? No
TEST MEDIUM
- Volume used/treatment: 0.45 mL of the test substance solution in THF was added to 50 mL of the buffer solution at the start of the hydrolysis test.
- Kind and purity of water: Milli-Q water
- Preparation of test medium: A 0.003 M (590 µg/g) test substance solution in tetrahydrofuran was prepared gravimetrically using a verified and calibrated analytical balance. The test substance solution composition was chosen to target a final spiked buffer concentration of 0.00003 M (~5 ppm)test substance.
- Renewal of test solution: Not required.
- Identity and concentration of co-solvent: Tetrahydrofuran (THF), <1% v/v
OTHER TEST CONDITIONS
- Adjustment of pH: No pH adjustment was carried out during the test.
- Dissolved oxygen: No details given. - Duration:
- 2.2 min
- pH:
- 4
- Initial conc. measured:
- 30 µmol/L
- Duration:
- 3 min
- pH:
- 4
- Initial conc. measured:
- 30 µmol/L
- Duration:
- 2.5 min
- pH:
- 7
- Initial conc. measured:
- 30 µmol/L
- Duration:
- 7.5 min
- pH:
- 7
- Initial conc. measured:
- 30 µmol/L
- Duration:
- 1.3 min
- pH:
- 9
- Initial conc. measured:
- 30 µmol/L
- Duration:
- 3 min
- pH:
- 9
- Initial conc. measured:
- 30 µmol/L
- Number of replicates:
- 2 at each pH (4, 7 and 9)
- Positive controls:
- not specified
- Negative controls:
- not specified
- Statistical methods:
- Since the hydrolysis was so rapid, there was insufficient data to use statistical methods to interpret the results.
- Preliminary study:
- The substance is known to be unstable at environmentally relevant temperatures, therefore, no preliminary study was required.
- Transformation products:
- yes
- No.:
- #1
- No.:
- #2
- Details on hydrolysis and appearance of transformation product(s):
- The hydrolysis of 1,1,1,3,3,3-hexamethyldisilazane to form ammonium ion and trimethylsilanol is well established. Hydrolysis of the Si-N bond results in the formation of amines/ammonia and silanols as co-products. (see Bazant, V.; Chvalovsky, V. In Chemistry of Organosilicon Compounds; Organosilicon Compounds Volume 1; Academic Press Inc.: New York, 1965; pp. 85-86.).
The analytical method used in this study measured formation of one of the co-products, ammonia, as ammonium ion. - Key result
- pH:
- 4
- Temp.:
- 1.5 °C
- DT50:
- <= 0.04 min
- Remarks on result:
- other: This value represents an estimated upper limit of the hydrolysis half-life. It refers to disappearance of the test material (based on ammonium ion concentration).
- Key result
- pH:
- 7
- Temp.:
- 1.5 °C
- DT50:
- <= 0.5 min
- Remarks on result:
- other: This value represents an estimated upper limit of the hydrolysis half-life. It refers to disappearance of the test material (based on ammonium ion concentration).
- Key result
- pH:
- 9
- Temp.:
- 1.5 °C
- DT50:
- <= 0.1 min
- Remarks on result:
- other: This value represents an estimated upper limit of the hydrolysis half-life. It refers to disappearance of the test material (based on ammonium ion concentration).
- Other kinetic parameters:
- None determined.
- Details on results:
- TEST CONDITIONS
- pH, sterility, temperature, and other experimental conditions maintained throughout the study: Yes
MAJOR TRANSFORMATION PRODUCTS
The ammonium ion concentration was measured over the course of the hydrolysis. The ratios of measured to theoretical (based on complete hydrolysis) ammonium ion concentration for duplicate measurements at pH 4, 7 and 9 were 109-136%, 96-98% and 96-104%, respectively.
No other transformation products were identified during the test.
PATHWAYS OF HYDROLYSIS
The proposed three step reaction scheme is shown below:
- Step 1: (CH3)3SiNHSi(CH3)3 + H2O → (CH3)3SiNH2 + (CH3)3SiOH
- Step 2: (CH3)3SiNH2 + H2O + (CH3)3SiOH → NH3 + 2 (CH3)3SiOH
- Step 3: NH3 + H2O → NH4+OH-
(see Bazant, V.; Chvalovsky, V. In Chemistry of Organosilicon Compounds; Organosilicon Compounds Volume 1; Academic Press Inc.: New York, 1965; pp. 85-86.). - Conclusions:
- A hydrolysis half-life of ≤0.5 minutes at pH 7 and 1.5°C was determined in a reliable study conducted according to an appropriate test protocol.
Reference
Since the hydrolysis was so rapid, there was insufficient data to determine rate constants for the hydrolysis reactions by regression modelling.
First order or pseudo-first order behaviour could not be confirmed because: (a) sparse nature of the data during the critical portion of the process,
b) the inherent limitation associated with measuring co-product concentration for consecutive reactions. Although rate constants and half-lives could not be determined quantitatively, the data was adequate for estimating the upper limit of t1/2.
Tables 1 shows key results for each hydrolysis test.
Table 1. Results
pH |
Replicate | Duration of test | % Theoretical [Cl-] at this temperature | Time used for t1/2 determination | % Theoretical [Cl-] at this time | t1/2 / s | |
4 |
A | 130 | 114 | 20 | 116 | 2 | |
4 |
B | 180 | 119 | 30 | 136 | 3 | |
7 |
A | 150 | 98 | 130 | 98 | 13 | |
7 | B | 450 | 96 | 440 | 96 | 44 | |
9 | A | 80 | 104 | 60 | 99 | 6 | |
9 | B | 180 | 116 | 60 | 98 | 6 |
* The time at which hydrolysis was deemed complete because two ammonium ion concentration readings were at least within 5% of the expected ammonium ion concentration.
The half-life at each pH is the average of the two replicates: 2.5 s, 28.5 s, and 6 s at pH 4, 7, and 9, respectively.
Description of key information
Hydrolysis: Half-life << 1 minute at 25°C and pH 4, pH 7 and pH 9 (analogue read-across)
Key value for chemical safety assessment
Additional information
No hydrolysis study is available for the submission substance N-(dimethylvinylsilyl)-1,1-dimethyl-1-vinylsilylamine (CAS 7691-02-3). However, a reliable study conducted in accordance with OECD Test Guideline 111 is available for the related substance 1,1,1,3,3,3-hexamethyldisilazane (CAS 999-97-3). 1,1,1,3,3,3-Hexamethyldisilazane is fully hydrolysed within a few minutes at pH 4, pH 7 and pH 9 and 1.5°C. The half-lives were determined to be ≤0.04 min at pH 4, ≤0.5 min at pH 7, and ≤0.1 min at pH 9 and 1.5°C (Dow Corning Corporation 2006). Another study conducted according to EC Method C10 supports very rapid hydrolysis of the substance with half-life of <150 minutes at pH 4, pH 7, pH 9 and 50°C (Wacker 1991); the study was determined to be reliable with restrictions since the test concentration exceeded the solubility of the substance.
The evidence suggests that organosilicon substances which have the structural feature Si-N (silazane) will hydrolyse extremely rapidly (half-life less than 1 minute) at pH 7 and 25°C to Si-OH and the corresponding amine or ammonia. This conclusion may validly be read-across in the absence of experimental data. It is not possible or necessary to attempt a quantitative prediction of rate or half-life because the chemical safety assessment is not sensitive to this uncertainty within this range. For substances with Si-N groups, the presence of other structural features does not impact the rate of reaction for the Si-N group(s) significantly. The reaction is typically so rapid that its precise half-life is not significant. Additional information is given in a supporting report (PFA 2013ae) attached in section 13.
[N-(Dimethylvinylsilyl)-1,1-dimethyl-1-vinylsilylamine is structurally very similar to 1,1,1,3,3,3-hexamethyldisilazane, with one methyl group on each silicon in the read-across substance being replaced with a vinyl group in the submission substance. Consideration of the likely mechanisms of reaction and evidence from the related category of alkoxysilanes (Peter Fisk Associates 2014a), indicate that this substitution could cause the registration substance to react faster than the read-across substance. Thus, the hydrolysis half-life of the submission substance is predicted to be ≤0.04 min at pH 4, ≤0.5 min at pH 7, and ≤0.1 at pH 9 and 1.5°C.
Therefore, it can be concluded that the submission substance will hydrolyse very rapidly under environmentally-relevant conditions and no further testing is necessary.
For an acid-base catalysed reaction in buffered solution, the measured rate constant is a linear combination of terms describing contributions from the uncatalyzed reaction as well as catalysis by hydronium, hydroxide, and general acids or bases.
kobs = k0 + kH3O+[H3O+] + kOH-[OH-] + ka[acid] + kb[base]
At extremes of pH and under standard hydrolysis test conditions, it is reasonable to suggest that the rate of hydrolysis is dominated by either the hydronium or hydroxide catalysed mechanism.
Therefore, at low pH:
kobs ≈kH3O+[H3O+]
At pH 4 [H3O+] = 10-4 mol dm-3 and at pH 2 [H3O+] = 10-2 mol dm-3; therefore, kobs at pH 2 should be approximately 100 times greater than kobs at pH 4.
The half-life of a substance at pH 2 is calculated based on:
t1/2(pH 2) = t1/2(pH 4) / 100
The calculated half-life of N-(dimethylvinylsilyl)-1,1-dimethyl-1-vinylsilylamine at pH 2 is therefore <0.0004 minutes (0.02 seconds). However, it is not appropriate or necessary to attempt to predict accurately when the half-life is less than 5-10 seconds. As a worst-case it can therefore be considered that the half-life of the substance at pH 2 and 20-25°C is approximately 5 seconds.
Reaction rate increases with temperature therefore hydrolysis will be faster at physiologically relevant temperatures compared to standard laboratory conditions. Under ideal conditions, hydrolysis rate can be recalculated according to the equation:
DT50(XºC) = DT50(T) * e(0.08.(T-X))
Where T = temperature for which data are available and X = target temperature.
Thus, for N-(dimethylvinylsilyl)-1,1-dimethyl-1-vinylsilylamine the predicted hydrolysis half-life at 37.5ºC and pH 7 (relevant for lungs and blood) is <2 seconds. As discussed above, it is appropriate to considered that the half-life at pH 7 and 37.5 ºC is approximately 5 seconds. At 37.5ºC and pH 2 (relevant for conditions in the stomach following oral exposure), it is not appropriate to apply any further correction for temperature to the limit value and the hydrolysis half-life is therefore approximately 5 seconds.
The hydrolysis products for the submission substance are dimethylvinylsilanol and ammonia.
NH3 exists in the aquatic environment in equilibrium with the ammonium ion, NH4+. Under normal environmental conditions, the NH4+ ion predominate.
The hydrolysis half-lives of substances used for read-across in other sections are discussed below.
Hydrolysis of the read-across substance 1,1,1,3,3,3-hexamethyldisilazane (CAS No: 999-97-3)
Data for the substance, 1,1,1,3,3,3-hexamethyldisilazane (CAS 999-97-3) are read-across to the submission substance [N-(dimethylvinylsilyl)-1,1-dimethyl-1-vinylsilylamine for the following endpoints, hydrolysis, short-term toxicity to fish; short-term toxicity to aquatic invertebrates; toxicity to aquatic algae; acute toxicity oral; acute toxicity inhalation; acute toxicity dermal and eye irritation. The silanol hydrolysis product of the two substances is relevant to this read-across, as discussed in the relevant section for each endpoint.
The hydrolysis half-lives of 1,1,1,3,3,3-hexamethyldisilazane are discussed above for the submission substance.
The hydrolysis products of 1,1,1,3,3,3-hexamethyldisilazane are trimethylsilanol and ammonia.
Hydrolysis of the read-across substance trimethoxy(vinyl)silane (CAS 2768-02-7)
Data for the substance trimethoxy(vinyl)silane (CAS 2768-02-7) are used as supporting information for the following endpoints, short-term toxicity to fish; short-term toxicity to aquatic invertebrates; long-term toxicity to aquatic invertebrates and toxicity to aquatic algae. The hydrolysis half-lives and the hydrolysis products of the two substances are relevant for the use of the studies as supporting information as discussed in the relevant section for each endpoint.
Trimethoxy(vinyl)silane has measured half-lives of <10 minutes at pH 4, <2.4 hours at pH 7 and <10 minutes at pH 9 and 50°C in a preliminary study according to OECD 111. Also, it has predicted half-lives at 20-25ºC of 0.04 h (2 minutes) at pH 4, 0.1 h at pH 5 and 7, and 0.004 h (14 seconds) at pH 9. In a secondary source to which reliability could not be assigned, half-lives of 0.24 h at pH 7 and 0.58 h at pH 4 and 23°C were reported for trimethoxy(vinyl)silane.
The hydrolysis products are vinylsilanetriol and ethanol.
Hydrolysis of the read-across substance dichloro(methyl)(vinyl)silane (CAS 124-70-9)
Data for the substance dichloro(methyl)(vinyl)silane (CAS 124-70-9) are read-across to the submission substance N-(dimethylvinylsilyl)-1,1-dimethyl-1-vinylsilylamine for the toxicity to microorganisms endpoint. The hydrolysis half-lives and silanol hydrolysis product of the two substances is relevant to this read-across, as discussed in the relevant section for this endpoint.
For dichloro(methyl)(vinyl)silane, hydrolysis half-lives are read-across from the related substance dichloro(dimethyl)silane (CAS 75-78-5). Half-lives of approximately 0.2 minutes at pH 4, approximately 0.3 minutes at pH 7 and approximately 0.1 minutes at pH 9 and 1.5°C were obtained in accordance with a relevant test method (Dow Corning Corporation 2001).
These half-lives relate to degradation of the parent substance to give methylsilanediol and hydrochloric acid.
Reference:
PFA (2013ae). Hydrolysis: 1c. Silazanes analogue report. Report number: PFA.300.005.001
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.