Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 APR 2021 - 04 MAY 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 59 Sieve Analysis
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 169 Tap Density of Water Dispersible Granules
Deviations:
no
GLP compliance:
no
Type of method:
sieving
Type of particle tested:
other: sample as such
Type of distribution:
mass based distribution
No.:
#1
Size:
< 45 µm
Distribution:
0 %
No.:
#2
Size:
> 45 - < 63 µm
Distribution:
0 %
No.:
#3
Size:
> 63 - < 100 µm
Distribution:
0 %
No.:
#4
Size:
> 100 - < 250 µm
Distribution:
2.66 %
No.:
#5
Size:
> 250 - < 500 µm
Distribution:
26.95 %
No.:
#6
Size:
> 500 - < 1 000 µm
Distribution:
55.22 %
No.:
#7
Size:
> 1 000 - < 2 000 µm
Distribution:
12.42 %
No.:
#8
Size:
> 2 000 - < 4 000 µm
Distribution:
0.22 %
No.:
#9
Size:
> 4 000 µm
Distribution:
0.65 %
Conclusions:
The particle size distribution of the sample was found to be between 250 μm and 2000 μm.
Executive summary:

The particle size distribution test was carried out according to CIPAC MT 59, 170 and 169, using 8 sieves with mesh size of 4, 2, 1 mm, 500, 250, 100, 63, 45 μm respectively. The particle size distribution of sample found to be between 250 μm and 2000 μm.

Description of key information

The particle size distribution test was carried out according to internationally accepted guideline CIPAC MT 59, 170 and 169, using 8 sieves with mesh size of 4, 2, 1 mm, 500, 250, 100, 63, 45 μm respectively. The particle size distribution of sample found to be between 250 μm and 2000 μm.

Additional information