Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12.10.2021 - 27.10.2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: UN Manual of Tests and Criteria: Test N.4 (Test method for self-heating substances)
Version / remarks:
2019
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks on result:
no self ignition observed under the test conditions

The test item was exposed to air at the temperature of 140 °C in a 100 mm wire mesh cube. A negative result was obtained; therefore, no further testing was necessary.

Based on this result, the test item should not be classified as a self-heating substance.

Conclusions:
A negative result was obtained, regarding the self-heating properties of the test item. Based on this result, the test item should not be classified as a self-heating substance.
In conclusion the substance is not auto inflammable. Hence, no self ignition temperature was determined.
Executive summary:

The self-heating properties of the test item was assessed according to the UN manual N.4 under GLP compliance.The test item was exposed to air at the temperature of 140 °C in a 100 mm wire mesh cube. A negative result was obtained; therefore, no further testing was necessary. Based on this result, the test item should not be classified as a self-heating substance. In conclusion the substance is not auto inflammable. Hence, no self ignition temperature was determined.


 

Description of key information

The self-heating properties of the test item was assessed according to the UN manual N.4 under GLP compliance.The test item was exposed to air at the temperature of 140 °C in a 100 mm wire mesh cube. A negative result was obtained; therefore, no further testing was necessary. Based on this result, the test item should not be classified as a self-heating substance. In conclusion the substance is not auto inflammable. Hence, no self ignition temperature was determined.

Key value for chemical safety assessment

Additional information