Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-12-09 to 2009-01-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: UN 33.2.1.4 Test N1 (Burning rate test)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3,4-dichloroaniline
EC Number:
202-448-4
EC Name:
3,4-dichloroaniline
Cas Number:
95-76-1
Molecular formula:
C6H5Cl2N
IUPAC Name:
3,4-dichloroaniline
Details on test material:
- Name of test material (as cited in study report): 3,4-dichloroaniline
- Physical state: solid molten mass
- Analytical purity: 99.7 %
- Purity test date: 2008-10-28
- Lot/batch No.: CHNHF E0495
-

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The substance in its delivery state was measured. The test substance melted when approached by the ignition flame. The substance didn't burn down or burn up. No further testing was required.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Executive summary:

Heinz, 2009

3,4-Dichloroaniline melted when approached by the ignition flame. The substance didn't burn down or burn up.

Therefore 3,4-Dichloroaniline is classified as no readily combustible solid when the burning rate was tested according to the UN Test 33.2.1.4.1.